DRYER,
STRAINER & DISTRIBUTER
MUFFLER / ACCUMULATOR
DRYER

| The filter dryer is generally use in all refrigerators,
air conditioners, show cases, vending machines and freezers.
The purpose of dryers is not only to eliminate the free water
in the system, but also to prevent the system from contaminants
and undesirable acids. |

Body O.D Size
(mm) |
Thickness
(mm) |
Molecular Sieves
weight (g) |
ln-let I.D. Size
(mm) |
Out-let I.D. Size
(mm) |
Screen
Size |
| ¡§¨£ 15.88 |
0.51 |
5-10 |
¡§¨£ 4.0-9.6 |
¡§¨£ 1.9-6.5 |
REF : 140/150 mesh
Air-Con :60-120 mesh
(according to the customer's requst) |
| ¡§¨£ 18.8 |
0.51 |
8-15 |
¡§¨£ 4.0-9.6 |
¡§¨£ 1.9-6.5 |
| ¡§¨£ 25.4 |
0.635 |
10-20 |
¡§¨£ 6.4-9.7 |
¡§¨£ 3.0-9.7 |
| ¡§¨£ 31.75 |
0.8 |
15-35 |
¡§¨£ 6.4-9.7 |
¡§¨£ 6.4-9.7 |
| ¡§¨£ 41.3 |
0.8 |
30-45 |
¡§¨£ 12.5-19.0 |
¡§¨£ 12.5-19.0 |

|
Other size beyond the above range may be available according
to the customer's request. |
| -Double-in let type dryers are also available
according to the customer's request. |
| -Dryers can be supplied by any packing methods
which are in vacuum aluminum foil bag or in tin can or with
airtight plastic cap. |
| -Various type of UOP's molecular sieves are available
as below according to the compatibility of refrigerant being
used. |
| |
| Refrigerant |
4A XH5 |
4A XH6 |
XH7 |
XH9 |
| R-12 |
¢®Ý |
¢®Û |
¢®Û |
¢®Û |
| R-22 |
|
¢®Ý |
|
¢®Û |
| R-500 |
|
¢®Û |
|
¢®Ý |
| R-502 |
|
¢®Ý |
|
¢®Û |
| R-134a |
|
¢®Û |
¢®Ý |
¢®Û |
| ¢®Ý : Best choice, ¢®Û
: Compatible |
STRAINER & DISTRIBUTER
|
Strainers and distributor are usually used in
room air conditioners to protect refrigeration components including
valves, compressors and capillary tubes from system contaminants.
The proper selection is based on mainly:
max. operating pressure
contaminants present in the system
The body is made of seamless copper tube and provided with a
phosphor bronze or stainless steel screen inside. |
MUFFLER
|
Mufflers are normally used to reduce compressor
noise which is usually caused by the pressure pulses of the
compressor. |
ACCUMULATOR
|
Accumulators are usually used to prevent possible
liquid refrigerant to reach the motor compressor. For the proper
size selection of an accumulator, volume of refrigerant and
operational pressure should be considered. Mufflers are normally
used to reduce compressor noise which is usually caused by the
pressure pulses of the compressor. |
|
|