Products & Business Line > Component List > BIMETAL THERMOSTAT & THERMAL FUSE

BIMETAL THERMOSTAT & THERMAL FUSE

Applications Micro wave Ovens, Refrigerators, Vending Machines,
Hot Water Heaters, Boilers, Tableware Dryers, etc
Function & Features - Automatic temperature control and prevention from overheating
- Small size with high current rating and low internal resistance

* TERMINAL PART : Fasten #250, #187
* TERMINAL APPERANCE : HORIZONTAL TYPE, VERTICAL TYPE
* BRACKET PITCH : 23.8mm, 30.0mm

Safety Certificates UL File No. E126365
CSA File No. 085546
VDE File No. 087822

Specifications
Rated Current AC 125V/15a, 250V/7.5A
Temperature Range -20¡É to 150¡É
Reset Temperature
On/Off Differential Min. 10¡É, Normal 15 to 25¡É
Temp. Tolerance Operating or Reset Temp.¡¾3¡É Min.(standard ¡¾5¡É)
Life Cycle 10000 cycle Min. at rated load
Dielectric Withstand AC 1.8kV for 1 second
Insulation Resistance 100M§Ù Min.
Internal Resistance 100m§Ù Max.



Applications Boilers, Hot Water Heaters, Table¡i¯is ware Heaters,
Vending Machines, Vacuum Cleaners and
Electric Stoves, etc.
Function & Features - Automatic Prevention from Overheating
- Manual Reset Type
- Small and Simple Shape

* TERMINAL PART : Fasten #250, #187
* TERMINAL APPERANCE : HORIZONTAL TYPE, VERTICAL TYPE
* BRACKET PITCH : 23.8mm, 30.0mm
Safety Certificates UL File NO. E126365
CSA File NO. 085546

Specifications
Rated Current AC 125V/15VA, 250V/7.5A
Temperature Range 50¡É to 150¡É
Reset_Temperature 0¡É Max.
On/Off Differential
Temp. Tolerance Operating Temp. ¡¾4¡É Min.(standard ¡¾5¡É)
Life Cycle 100,000 cycles Min. at rated
Dielectric Withstand AC 1.8kV for 1 second
Insulation Resistance 100M§Ù Min.
Internal Resistance 100m§Ù Max.
* Remarks : Any requirement on the terminals, caps, brackets or contacts are acceptable


Applications Refrigerators, Show Cases cold storage, freezing, thermal insulation),
Ice Maker, etc
Function & Features -Temperature automatic control for removing frost and for protecting
the frozen rupture in the cold storage or freezing systems
-Easy to install at the small or narrow space as slim shape
-Small size with high contacting capacitance
-Available waterproof and dustproof types with welding vinyl tube on
the part


Remarks : Any requirement on the caps, brackets or contacts are
acceptable.
Safety Certificates UL File No. E126365
CSA File No. 085546
VDE File No. 132011

Specifications
Rated Current AC 125V/15VA, 250V/7.5A
Temperature Range -20¡É to 150¡É
Reset_Temperature
On/Off Differential Min. 10¡É, Normal 15 to 25¡É
Temp. Tolerance Operating or Reset Temp.¡¾3¡É Min.(standard ¡¾5¡É)
Life Cycle 100,000 cycle Min.at rated
Dielectric Withstand AC 1.8kV for 1 second
Insulation Resistance 100M§Ù Min.
Internal Resistance 100m§Ù Max.
* Remarks : Any requirement on the terminals, caps, brackets or contacts are acceptable


Applications Refrigerators, Show Cases (cold storage, freezing, thermal insulation),
Ice Maker, etc
Function & Features -Temperature automatic control for removing frost and for protecting
the frozen rupture in the cold storage or freezing systems
-Easy to install at the small or narrow space as slim shape
-Small size with high contacting capacitance
-Available waterproof and dustproof types with welding vinyl tube on
the part

Remarks : Any requirement on the caps,
brackets or contacts are acceptable.
Safety Certificates UL File NO. E126365
CSA File NO. 085546

Specifications
Rated Current AC 125V/10VA, 250V/5A
Temperature Range -20¡É to 90¡É
On/Off Differential 10¡É Min.
Temp. Tolerance Operating or Reset Temp.¡¾3¡É Min.(standard ¡¾5¡É)
Life Cycle 100,000 cycle Min.at rated
Dielectric Withstand AC 1.8kV for 1 second
Insulation Resistance 100M§Ù Min.
Internal Resistance 100m§Ù Max.
* Remarks : Any requirement on the terminals, caps, brackets or contacts are acceptable


Applications Refrigerators, Show Cases (cold storage, freezing, thermal insulation),
Ice Maker, etc

Function & Featuresv [ Secifications ]
Electrical Rating : AC 250V/10A Max.
Cutoff Temperatures : 72(+0, -4) ¡iÉi¸. 77(+0, -4) ¡iÉi¸.

Automatic prevention from overheating.


Remarks : Any requirement on the thermal fuse or lead wires contacts
are acceptable